Sign In | Join Free | My ledscreensign.com
China Zhengzhou Linker Medical Equipment Co., Ltd. logo
Zhengzhou Linker Medical Equipment Co., Ltd.
Let the world love China dental products!
Active Member

7 Years

Home > Dental Autoclave Sterilizer >

Pressure Steam Class N 18L SS Dental Autoclave Sterilizer

Zhengzhou Linker Medical Equipment Co., Ltd.
Contact Now

Pressure Steam Class N 18L SS Dental Autoclave Sterilizer

  • 1
  • 2

Brand Name : Triumph

Model Number : TR-1

Certification : CE ISO FDA

Place of Origin : China

MOQ : 1pc

Price : Negotiable

Payment Terms : L/C, D/A, D/P, T/T, , MoneyGram

Supply Ability : 500pcs/Month

Delivery Time : 1 day After Got Payment

Packaging Details : 1pc/carton 28KG/Carton

Working Pressure : 134 degree

Voltage : 110V / 220V

Weight : 28kg

Capacity : 18L

Wrranty : 1Year

After Sale Service : Online Technical Support

Contact Now

USA Apixia Dental X Ray Machine PSP 3D Scanner

Specification:
Chamber capacity Ø 250XD350MM
Inside capacity 18L
Outside size 60*39*36
Sterlize temperature 122º C &132º C
Sterilize Pressure (Mpa) 0.12Mpa & 0.23Mpa
Sterilize Time 25Min & 6Min
No dry function
Heater 1000W
Material Quality Stainless Steel SUS#304 Boiler chamber surface with burnish
Surface deal with the machine foundation and the shell use high temperature baking varnish processing
Electric current 110V9A, 220V 4.5A
Manual give the water

Name of Each Part
1.Pressure gauge
2.Error indicator
3.134C light
4.Door bolt
5.Temp selector switch
6.Power switch
8.Steam discharge switch
9.Door handle

Size 64×46×41cm
Feature Economic Style
Application Dental Areal
Voltage 220V,50Hz or 110V,60Hz

Pressure Steam Class N 18L SS Dental Autoclave Sterilizer

Pressure Steam Class N 18L SS Dental Autoclave Sterilizer

Use Step:

Step 1:pouring the 800ml Distilled water into the chamber.

Step 2:will need the sterilization instrument to put in the tray.

Step 3:Closed the door and insert the bolt

Step 4:Close the steamexhaust switch.

Step 5:Select the temperature you need to (121℃or134℃)

Step 6:Turns on the POWER switch.(starts to work

Disinfect Process

Heating

----First emissions steam

----Second emissions steam

-----The temperature rise arrives at the disinfection temperature

----Starts to disinfect

----The disinfection completes

----Buzzer sound

-----The buzzer stops the sound

-----Turns on the steam emissions switch

----Waited for that the Pressure gauge nulling operation

----Waits for 6~8 minutes

----Opens the door

----The disinfection completes

When the door cannot open.
1: don't hard revolving door cover handle.
(if the hard rotating handle, will cause machine damage.)
2: the solution:
find the machine safety valve in the rear of the TAB,
pull the TAB out about3 ~ 4 minutes after let go.
Can rotate handle turnstiles cover to move.

Caution:
1.After the completion of disinfection. Please to wait for 10 ninutes.
Belore open the DOOR(Do not close the power switch and close the steam
emissions switch).
2.Before each use. Must supply water 800ml. (Distilled water is the
bast)
3.Pleaso closo steam missions switch. Before In the disinfection.
4.Do not use any corrosive or chemical water as the disinfectlon.
5.Do not share the same electricoutlet with other electrical apparetus.
6.Please pay attention to correct voltage and frequency.
7.Connect steam exhaust pipe with the steam vent, Before operation.


Trouble Shooting:
When disinfection work has not completed,the buzzer makes a sound and
the Error indicator twinkle.Please to check: Turns on the emissions steam
switch.machine steam and pressure emissions.(Do not off the power
switch,turns on the steam switch first)10 minutes later opens the machine
door.(Very important)
Condlton 1:Check the disinfection room to have the sufficient water
surce.Temperature protection switch work stop heating pipe work. (Wait for
15min later,lest the temperature protection switch restore normally.Joins
the water source, before each time uses the machineJoins 800ml.)(Doing
2-3 times ofandon the power switch movementafter. Turns on the powor
switch,machine to work)
Condltlon 2:Sudden power falure(Turn off and on the power swutch 2~3
tlmes.machine to normal work.
Condltlon 3: Can openthe door cover. 1-1 completion ofdisinfection.
afterwork. Hearbuzzersounded. 1 2.The firstopenthe steamswitch.Let
steam discharge. 1-3.Open the door cover. 1-4.Turn off the power switch
CondHon 4: The fllowing code shows.E1 and E4 (high temperature.
Reason:CHAMBER inside water enough. Solution: open the door cover,
wait for 5 minutes. Add water. Repeat off and turn on the power switch 2.)E3
(reason: the machine is in operation, power failure or instabillty. Solution:
repetition and opens and closes thepower switch 2time.

Contact Us:

DepartmentDaisy Dai(Ms)/Export

Linker Dental Group Limited
Web: www.zzlinker.com
Skype: zzlinker3

Email: daisy@zzlinker.com
Mobile/whatsapp/wechat:0086 13849058625


Product Tags:

SS Dental Autoclave Sterilizer

      

18L Dental Autoclave Sterilizer

      

134 Degree Medical Steam Sterilizer

      
Quality Pressure Steam Class N 18L SS Dental Autoclave Sterilizer for sale

Pressure Steam Class N 18L SS Dental Autoclave Sterilizer Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhengzhou Linker Medical Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)